<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>37203</ErrorNumber>
<ErrorFamily>Head Interface</ErrorFamily>
<ErrorMessage>
HIF: The length of the monitor command is invalid
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
Monitor redirection allows the user access to the diagnostic port of the
exposure head using the diagnostic port of the host.  When monitor redirection
is enabled in passthrough mode, the user can access the diagnostic port of
both the host and exposure head.  The host processes all received characters
and handles all monitor commands.  The "th2" command is used to redirect
monitor commands from the host to the exposure head.  However, the "th2"
command can only redirect monitor commands less than 128 characters in length.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Reduce the length of the monitor command.
</text></DescriptionText>
</OperatorAction>
<Availability>
<DescriptionText><text>
This error is reported.
</text></DescriptionText>
</Availability>
<Cause>
The length of the monitor command is invalid.
</Cause>
<LastModified>
30-Jul-2002
</LastModified>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:08 2008 PST
</Updated>
<Links>
</Links>
</Error>